OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
6-38
L1
and
L2
L3
and
L4
Q
19 DURESS
AC
LOSS
Q 20
KEYPAD
✱
& #
LOW BAT
Q 21*
OPEN\CLOSE
N/A
Q 22
KEYPAD 7 & 9 PANIC
KEYPAD 1 & 3 PANIC
Q 23
KEY TAMPER
CS TEST
Q
24* FALSE
ALARM
(exit error - L1, recent close - L2)
FALSE ALARM
(lockout - L3, cancel - L4)
Q 25
BELL/SIREN SUPERVISION
KEYPAD TAMPER
Q
26* BYPASS
(bypass - L1, bypass restore - L2)
TROUBLE
(fire trouble - L3, zone trouble -L4)
Q 27
DOWNLOAD
WALK TEST
Q 28
EVENT LOG 90% FULL
EVENT LOG 100% FULL
Q
29* SUPERVISION
(n/a, tamper - L2)
SUPERVISION
(n/a, trouble restore - L4)
Q 30
ARM DISABLE
(must be “DD” if disable
arming is set in Q 11, L3)
CLOCK SET
Q 31
UP-ABOUT**
CLOCK FAIL
* These questions have single-digit report code entries for each location. See
Programming Form for details.
** Up and About: Programming a reporting code for Up and About enables this
function. For this function, if no controlled zone is violated within a 24-hour
period (beginning at midnight), a signal is sent to the central station. This
can serve as a safety feature for elderly, infirm, or disabled persons.
QUESTION 32 FIRST DOUBLED ZONE
N/U N/U
L1 L2
L3 L4
First Doubled Zone
This question sets the first hardwire doubled zone. Enter digits as follows:
L1: Enter the first digit of first doubled zone number. This option doubles the number of hardwired
zones from the first zone entered here upward. That is, loop 1 becomes zones 1 and 2, loop 2
becomes zones 3 and 4, etc. This can provide up to 8 (OMNI-400’s) or 12 (OMNI-600’s) hardwire
zones.
L2: Enter the second digit of first doubled zone number.
REMINDER: Zones defined as doubled zones must be programmed as EOL. Additionally, different
EOL resistor values must be used as described in Section 2: System Wiring and Hookup and Section 4:
System Configurations.