2. User number 1 programs all user codes (01
–
15); cannot be deleted.
3. User numbers 10
–
14 will be the system "door strike" code if any trigger is defined as a door strike
trigger. If any of the output triggers are defined as door strike, then entry of this user code will
activate that trigger for a period that is defined in Submode 1, Question 30, Locations 3 and 4. In
addition, there is an option to allow all user codes to act as a door strike code. If this option is
selected (Submode 1, Question 10, L1), then all users can activate the door strike through the [#] +
[5] + [7] command (See “Quick Command Modes”). If a door strike (or access) trigger is not defined,
then this user code can be utilized as a normal user code.
4. User number 15 (Duress; enabled in Submode 1, Question 10, L1) will activate a system-wide
Duress code if there is a Duress CS report code programmed into Submode 2, Question 19, L1, L2. If
no CS code is defined in Question 19, then this user number will be a normal user code. In this
mode, an entry of the user number code will ARM or DISARM the system and transmit the ambush
code to the central station. Furthermore, if the CS transmission format contains the user number,
the user number will be transmitted. If a Duress transmission code has been programmed and a
user does not exist, it will not be possible to activate the Duress feature.
AUTHORITY LEVELS
Each user is assigned one of 4 authority levels, which determines the system functions that user can
perform.
Level
Functions Allowed
1
Primary Master can set time, assign other user codes, all system functions
2
Secondary Master, same as primary Master except cannot change the primary Master’s code
3
User can arm and disarm only
4
Limited user, same as level 3, except can disarm the system only if it was armed by another
user with level 4 authority (cannot disarm if armed by user of higher authority level).
4/6-DIGIT USER CODES
The system supports either 4- or 6-digit user codes. A bit option in Submode 1, Question 09, Location 3
selects if the user codes are to be 4 or 6 digits in length for the entire system. The default user code for
the master is 1234 with an authority level of 1. The system is defaulted to 4-digit user/installer code. If
the bit is set in installer mode, each currently programmed code will change to six digits by adding a
“00" before the known 4-digit code.
For example, if 4-digit codes are being changed to 6 digits and a user code was 1-2-3-4, it will become 0-
0-1-2-3-4. Conversely, if the user code length was 6, and it is changed back to 4 digits, the code 1-2-3-4-
5-6 will become 3-4-5-6.
Once “6-digit user codes” is selected, new codes entered can be any combination of 6 digits.
NOTE: Selecting “6-digit user codes” also affects the installer code by adding “00” to the code (default
installer code 2468 becomes 002468). Use Question 00 to enter a new installer code.
TO ADD OR CHANGE USERS:
Press
[CODE] + MASTER USER CODE + USER NO. + NEW USER CODE +
AUTHORITY LEVEL
where:
[CODE]
[CODE] button on keypad.
MASTER USER
4- or 6-digit* Master User code (user with authority level 1 or 2)