![background image](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062066.webp)
OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
6-30
For L2, make a selection from the table below.
L2
Entry
Arm
Away
Arm
Stay
Pager
Alert/Trouble
0
1
✔
2
✔
3
✔
✔
4
✔
5
✔
✔
6
✔
✔
7
✔
✔
✔
Arm Away/Stay: Selects the arming mode that the
designated soft key will activate. The soft key will force-
arm the system and bypass zones that are not ready.
Pager/Beeps Alert/Trouble: If selected, a message will
be sent to the pager when the designated soft key is
pressed. This can be used to send a “help me” message.
QUESTION 20 AUTO-ARM/KEYPAD TAMPER ENABLES
N/U N/U
L1 L2 L3 L4
Q 20, L1 —
This question enables auto-arming. See Question 21 for setting the auto-arm time. Enter
the L1 digit as follows:
L1
Entry
Auto-
arm
Audible
Arm
Warning
Instant
Arming
Stay
Arming
0
1
✔
3
✔
✔
5
✔
✔
7
✔
✔
✔
9
✔
✔
B
✔
✔
✔
D
✔ ✔
✔
F
✔ ✔ ✔
✔
Auto-arm: Arms the system in AWAY mode at time
specified in Programming Submode 1, Questions 21.
Audible Arm Warning: If enabled, allows an audible
keypad or bell sound (4 quick beeps) to warn of auto-
arming. If enabled, the 4 quick beeps will be emitted
every minute starting 3 minutes before the system is
automatically armed. At 30 seconds before arming, the
anel will follow the threshold options selected in
Submode 1, Question 12, Location 2.
Instant Auto-arming: Arms the system in the Instant
mode with entry delay disabled.
Stay Auto-arming: Arms the system in STAY mode.
UL
Must be programmed as “0” for UL installations.
NOTES:
•
All auto-arm modes will force-arm the system. This means any open zones at the time of auto-
arming will be bypassed. To report these bypassed zones, program a bypass code in Programming
Submode 2, Question 26, L1.
•
When you are using the ADEMCO Point ID reporting format and any auto-arm mode is enabled, a
PID code of 403 with a user number of 126 is sent to the central station when the system auto-arms.