![background image](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062040.webp)
OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
6-4
ALARM
FIRE
INSTANT
BYPASS
TRBL PAGE
STAY
SUPRVSN CANCELED
CHIME
BAT
NOT READY
PHONE TEST
TAMPER NO AC
21
FIXED
DIGITS
SUBMODE
INDICATORS
QUESTION
NUMBER
INDICATOR
LCD
DISPLAY
OMNI600-006-V0
Submode Indicators = STAY, INSTANT, and BYPASS indicators
The STAY, INSTANT, and BYPASS indicators provide the current submode number. The current
submode number is as follows:
STAY lit, INSTANT and BYPASS off = submode 1
STAY and INSTANT lit, BYPASS off = submode 2
NOTE: Submode 4 cannot be displayed on a fixed-word keypad. Submode 4 contains descriptive
information for display on an LCD keypad. Therefore, programming in submode 4 would be
meaningless on a fixed-word keypad.
Question Numbers = ALARM indicator and LCD display
While ALARM is lit, the LCD digits are displaying a question number. When a question number is
entered on the keypad, ALARM will light and the LCD digits will display the question number for 2
seconds before automatically changing to a display of the Location and Location Content. ALARM
extinguishes when the display switches to Location/Location Content.
Location and Location Contents = Fixed Digits and LCD display
The location number will normally be shown in the first-character position of the 2-character LCD
display. However, when the question contains more than 9 locations, the fixed digits will be used with
the first LCD character to indicate locations 10 through 19 (fixed digit 1 and the LCD character) or 20
through 29 (fixed digit 2 and the LCD character). While the location number is being displayed, the
content of the location is displayed in the second-character position of the 2-character LCD display.
KEY ENTRIES
The below listing provides the function of certain key sequences when a fixed-word keypad is used to
program the system.