OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
6-28
Q 16, L4: Dialer Delay —
Enter the L4 digit for the desired dialer delay from the following table.
L4
Entry
Dialer Delay
(Seconds)
L4
Entry
Dialer Delay
(Seconds)
L4
Entry
Dialer Delay
(Seconds)
L4
Entry
Dialer Delay
(Seconds)
0
15
4
40
8
90
C
180
1
20
5
50
9
105
D
210
2
25
6
60
A
120
E
240
3
30
7
75
B
150
F
255
UL
Must be programmed as “0” for UL installations.
QUESTION 18 SOFT KEY FUNCTIONS (1 & 3/7 & 9)
L1 L2
L3 L4
1 & 3 Keys
7 & 9 Keys
For L1 and L3, make selections from the table below (L1 = 1 & 3 keys; L3 = 7 & 9 keys).
NOTE: The functions programmed for soft keys 1 & 3 will also apply to the Panic/Arm-Only switch
input to the panel (terminal 16).
Sounder Options
Trigger/Relay Options
L1/L3
Entry
Silent
Keypad
Burg. Bell
Temporal
No Relay Mom. Seconds
Mom. Minutes
Toggle
0
✔
✔
1
✔
✔
2
✔
✔
3
✔
✔
4
✔
✔
5
✔
✔
6
✔
✔
7
✔
✔
8
✔
✔
9
✔
✔
A
✔
✔
B
✔
✔
C
✔
✔
D
✔
✔
E
✔
✔
F
✔
✔
Sounder Options: Selects the sounding that will occur when the designated soft keys are pressed.
Trigger/Relay Options: Selects the type of relay action when the designated soft keys are pressed.
See Questions 23–29 to program relays.