![FBII OMNI-400 EU Installation And Setup Manual Download Page 54](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062054.webp)
OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
6-18
Q 10, L1 —
Enter the L1 digit for the desired user options from the table below.
L1
Entry
User
On-line
User 15
Duress
No Code for
Door Strike
Door Strike
Users 10–14
0
1
✔
2
✔
3
✔
✔
4
✔
5
✔
✔
6
✔
✔
7
✔
✔
✔
8
✔
9
✔
✔
A
✔
✔
B
✔
✔
✔
C
✔
✔
D
✔
✔
✔
User On-line: Allows Quick Command
downloading (#9) while on the telephone with
the central station.
User 15 Duress: Allows a Duress Code to be
assigned. A Duress Code must be
programmed in Submode 2, Question 19, L1–
L2. If duress is not selected, then user 15
may be used as a standard user code.
No Code for Door Strike: Allows Quick
Command for door strike as #57 only.
Door Strike Users 10–14: Allows up to 5
codes to be assigned that, when used, will
activate the door strike trigger (trigger type
1E). See Questions 28 and 29 for
programming the trigger types and Questions
23–27 for programming relay types. If this
option is not selected, then users 10–14 may
be used as standard user codes.
E
✔
✔
✔
F
✔
✔
✔
✔
UL
Door Strikes have not been evaluated
for UL installations.
Q 10, L2
— Enter the L2 digit for the tamper, RTC, or tone burst options from the table below.
L2
Entry
Key
Tamper
Lockout
Installer
Reset
Tamper
Crystal
RTC
Tone
Burst
0
1
✔
2
✔
3
✔
✔
4
✔
5
✔
✔
6
✔
✔
7
✔
✔
✔
8
✔
9
✔
✔
A
✔
✔
B
✔
✔
✔
C
✔
✔
D
✔
✔
✔
E
✔
✔
✔
F
✔
✔
✔
✔
Key Tamper Lockout: If this option is selected, 21 key
presses at a keypad without a valid sequence (arm, disarm,
etc.) will disable all keypads for 20 minutes. Additionally, a
tamper message will be sent if programmed in
Programming Submode 2, Question 23, L1–L2.
Installer Reset Tamper: If selected, only the installer
can reset zone tamper conditions by using installer mode 6.
Crystal RTC: If selected, the control uses its internal
crystal as a reference for the Real Time Clock (RTC)
instead of the AC Mains input.
Tone Burst: If selected, the control emits a tone burst
when the following conditions occur:
•
Upon the control answering on a ring count
(programmable or 2-call method) of a remote download
connection.
•
After the control performs a callback to the download PC
and the downloader answers in both the attended and
unattended download modes.
This feature is required when using a modem that requires
a tone to operate.