![background image](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062072.webp)
OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
6-36
L4 Entry
L4
Entry
Stay Auto-
Stay
Chime Dial
Delay
0
1
✔
2
✔
3
✔
✔
4
✔
5
✔
✔
6
✔
✔
7
✔
✔
✔
8
✔
9
✔
✔
A
✔
✔
B
✔
✔
✔
C
✔
✔
D
✔
✔
✔
E
✔
✔
✔
F
✔
✔
✔
✔
Stay – If selected, zone will be bypassed if the system is armed
in STAY mode.
Auto-Stay – If selected, zone will be automatically bypassed if
a delay zone (e.g., entry/exit door) is not faulted during exit
delay.
Chime – If selected, a fault on this zone while the system is
disarmed will cause the keypad to emit a 1-second beep. When
selected, a keypad entry of [#] + [6] toggles this feature on and
off.
Dial Delay – If selected, transmission of alarms on this zone
will be delayed by the time selected in Submode 1, Question
16, Location 4. The items apply to dial delay:
•
When selected, dial delay affects Delay, Interior, Instant,
24-Hr Alarm, and the alarm portion (only) of 24-Hr Alarm
Trouble zones.
•
24-Hr Trouble, Day Zone Trouble, Fire Trouble, and the
trouble portion of 24-Hr Alarm Trouble zones are not
affected by the dial delay feature. These zone types will
automatically follow the dial delay programmed in Submode
1, Question 16, Location 4.
•
The system will not check for dial delay on any fire zone.
These zones have no delay on a fire alarm.
Typical Question 01–12 Layout
L1
L2
L3
L4
Zone config. silent/
stay/chime
Type swing
dial
delay
Q 01 ZONE 1 (type/attributes)
Q 05 ZONE 5 (type/attributes)
Q 09 ZONE 9 (type/attributes)*
Q 02 ZONE 2 (type/attributes)
Q 06 ZONE 6 (type/attributes)
Q 10 ZONE 10 (type/attributes)*
Q 03 ZONE 3 (type/attributes)
Q 07 ZONE 7 (type/attributes)
Q 11 ZONE 11 (type/attributes)*
Q 04 ZONE 4 (type/attributes)
Q 08 ZONE 8 (type/attributes)
Q 12 ZONE 12 (type/attributes)*
* Questions 09 through 12 are not used in the OMNI-400 or OMNI-400EU. These questions apply to
the OMNI-600 and OMNI-600EU ONLY.