![background image](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062026.webp)
OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
5-6
OMNI-LCD/XK-7LC
OMNI-KP
XK-108
Indicator LED Lit
Armed
Armed
Armed, Instant
Display
ON: INSTANT
INSTANT
N/A
The entire security system (interior and exterior) is armed at this time, eliminating the entry time
delay(s) that have been programmed into the system.
NOTE: The Instant mode can be enabled through programming Submode 1, Question 11, Location 1.
STAY/INSTANT ARMING
TO ARM: Press the [STAY] key; press the [INSTANT] key and enter a four-digit user code.
The STAY/INSTANT mode will arm the system with the characteristics of both the STAY and
INSTANT modes. The keypads will have the ARM, INSTANT, and STAY LEDs turned ON
continuously.
OMNI-LCD/XK-7LC
OMNI-KP
XK-108
Indicator LED Lit
Armed
Armed
Armed, Instant,
Stay
Display
ON: STAY/INS
STAY
INSTANT
N/A
The system will be armed with the interior zones bypassed and the delay zones instant.
NOTE: The STAY/INSTANT mode can be enabled through programming Question 11, Location 1.
DISARMING
TO DISARM: Enter any valid four-digit user code and the ARM LED will extinguish.
If an alarm condition exists or occurred while the system was armed, the respective zone LED will
blink rapidly. This condition is classified as Alarm Memory, and can be cleared by entering a valid user
code again. Note that a user with level 4 authority (limited user) can disarm the system only if it was
armed by a level 4 user.
RESET
Reset is accomplished through the entry of any valid user code. This can be used to reset the smoke
detectors attached to the system, silence any bells or sounders, or clear the keypad display.
BYPASS BY ZONE
Bypassing is enabled to temporarily exclude zones or points that are faulty or otherwise not ready for
operation, from activating the security system.
TO BYPASS by ZONE: Press the [BYPASS] key followed by any valid 4- or 6-digit user code, followed
by the zone number (01–08 for OMNI-400’s or 01–12 for OMNI-600’s) representing the zone to be
bypassed.
EXAMPLE: To bypass zone 6 (assume user code of 1234), press [BYPASS] + [1] + [2] + [3] + [4] + [0] +
[6].
QUICK BYPASS BY ZONE
Quick Bypassing is a programmable option (Question 11, Location 4), and allows the user to bypass
zones and points without using a user code.