OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
5-14
DISPLAY PANEL REVISION: # 55 (LCD Keypads Only)
Pressing [#] [5] [5] displays panel revision level on the LCD keypads.
The system exits this mode when the star [
✱
] key is pressed.
DOOR STRIKE: # 57
UL
DOOR STRIKE is not a permitted programming option for any UL installation.
The door strike trigger can be activated by pressing:
[
#] + [5] + [7] + USER CODE
–
OR–
[#] + [5] + [7]
if no code for strike is enabled (Submode 1, Question 10, L1)
At least one of the triggers must be defined as a door strike trigger in order to use this feature.
Note that the door strike can also be activated by users 10 through 14 if the door strike users option is
set (Submode 1, Question 10, L1).
CHANGE/VIEW PAGER NUMBER: # 58
If enabled (Submode 1, Question 13, L2), this [#] + [5] + [8] command can be used to change the pager
phone number. To change the pager phone number, press:
[#] + [5] + [8] + USER CODE + PHONE [#]
–
OR–
[#] + [5] + [8] + PHONE [#]
if a User Code is not required (Submode 1, Question 13, L2)
This mode times out in 10 seconds without saving the phone number if no key is pressed, or exits
without saving if the [
✱
] key is pressed.
DISPLAY/TOGGLE CHIME: # 6
If the Chime option is programmed for any of the zones (Submode 2, Questions 01–12, L4), then
pressing [#] + [6] will display and toggle (turn OFF/ON) the system chime. The system will exit this
mode either automatically (no keys pressed), or when the star [
✱
]
key is pressed.
TOGGLE PAGER OPEN/CLOSE REPORTS: # 8
Pressing [#] + [8] toggles (turns OFF/ON) the Open/Close reports being sent to the pager. To toggle
Open/Close Reports on, the following conditions must exist:
•
The system must not have an alarm or trouble condition.
•
The system must have the pager open or close enabled (Submode 1, Question 14, L4).
•
A pager phone number must be programmed (Submode 1, Question 04).
•
The Page Attempts option must be set (Submode 1, Question 10, L3).