![background image](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062055.webp)
Section 6. System Programming
6-19
Q 10, L3 —
Enter the L3 digit from the table below.
Pager
Attempts
L3
Entry
1
2
3
0
disabled
1
✔
2
✔
3
✔
Pager attempts: This sets the number of times the system will send a report
to a pager.
Q 10, L4
— Enter the L4 digit from the table below.
Swinger Count
L4
Entr
y
0
1
2
3
0
disabled
1
✔
2
✔
3
✔
Swinger Count: Sets the maximum number of messages (controlled zone
alarms or troubles) sent during an armed period.
QUESTION 11 ARMING OPTIONS
L1 L2 L3 L4
This question defines arming options. Enter the digits as follows:
Q 11, L1
— Enter the L1 digit from the table below.
L1
Entry
Stay
Arms
Stay
Instant
Arms
Away
Instant
Enabled
0
1
✔
4
✔
5
✔
✔
8
✔
9
✔
✔
Stay Arms Stay: If enabled, the system will arm in the STAY
mode by simply pressing the [STAY] key (user code not required).
Otherwise, the user must press the [STAY] key followed by the user
code to arm in STAY mode. When you are using the ADEMCO Point
ID reporting format and Stay Arms Stay is enabled, a PID code of
408 with a user number of 128 is sent to the central station when
the system is armed using the STAY key.
Instant Arms Away: If enabled, the system will arm in the AWAY
mode by pressing the [INSTANT] key. When you are using the
ADEMCO Point ID reporting format and Instant Arms Away is
enabled, a PID code of 408 with a user number of 128 is sent to the
central station when the system is armed using the INSTANT key.
Instant Enabled: If selected, allows the end user to arm in the
instant mode. Not available if INSTANT ARMS AWAY is selected.