![background image](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062029.webp)
Section 5. System Operation
5-9
USER NO.
Desired user number to be programmed (01–15).
NEW USER CODE
4- or 6-digit* user code for the new user. Valid digits are 0–9.
AUTHORITY LEVEL
The desired authority level for the new user.
*Depending on the whether the system is set for 4- or 6-digit security codes
Example: Define user number 03 with a code of 7493 and authority level 3. (Assume Master code is
1234) = CODE 1234 03 7493 3
An acknowledgment (steady tone) verifies a successful user code programming. A negative
acknowledgment (4 short tones) indicates unsuccessful programming. If additional user programming
is necessary, repeat the procedure listed above. If a dialing format is programmed that transmits
opening/closing by user ID, each user will report their user number.
User code programming can ONLY be performed while the system is DISARMED.
User Deletion
User codes (02–15) can be deleted from any keypad. Once deleted, their values are null.
TO DELETE USERS:
[CODE] + MASTER CODE + USER NO. + [#]
where:
[CODE]
[CODE] button on keypad.
MASTER CODE
Master User code.
USER NO.
Desired user number being deleted (02–15).
[#]
[#]
button.
Keypad Emergency Conditions
The system is capable of transmitting four keypad auxiliary conditions as follows:
CONDITION
KEYSTROKES
CS REPORT ENABLE
OPTIONS
(aud./silent; arm beeps; relays)
PANIC
# &
✱
(at the same time)
Submode 2, Question 20,
L1, L2
Immediate and unabortable
See Submode 1, Question
19, L1, L2
FIRE
7 & 9 (at the same time)
Submode 2, Question 22,
L1, L2
Immediate and unabortable
See Submode 1, Question
18, L3, L4
AUXILIARY
1 & 3 (at the same time)
Submode 2, Question 22,
L3, L4
Immediate and unabortable
See Submode 1, Question
18, L1, L2
DURESS
User code assigned to user
15
Submode 2, Question 19,
L1, L2
Immediate and unabortable
See Submode 1, Question
10, L1
The keypads have additional keys dedicated for emergency conditions. These can be activated by
pressing both keys at the same time (see “Keypads” in this section).
Audible Panic, Fire, and Audible Auxiliary can be RESET BY ENTERING ANY VALID USER CODE.