Section 6. System Programming
6-5
KEY ENTRY
FUNCTION
[#]
Advance to the next location within the current question; or advance to the
next question if the last location in the current question is already displayed.
[
✱
] + 00–99
Go to a specific question selected by 00 to 99.
[CODE] + 1–6
Enter A through F as data where:
[CODE] + [1] = A
[CODE] + [4] = D
[CODE] + [2] = B
[CODE] + [5] = E
[CODE] + [3] = C
[CODE] + [6] = F
[
✱
] + [BYPASS] + 1–2
Change mode where:
[
✱
] + [BYPASS] + [1] = submode 1
[
✱
] + [BYPASS] + [2] = submode 2
NOTE: Submode 4 is not accessible on the fixed-word keypad
[INSTANT]
Advance to the next question
[STAY]
Exit the programming mode
Installer Modes Summary
There are 9 installer modes in this panel.
TO ENTER INSTALLER MODES, press [CODE] + [
✱
] + Installer Code + X
where: [CODE]
CODE button
[
✱
] Star
(
✱
) button
Installer Code 4- or 6-digit Installer Code as programmed; default = 2468
X
Single digit indicating the installer mode, as follows:
1 INSTALLER KEYPAD PROGRAMMING
3 submodes:
1- System Options
2- Zone and Report Code Programming
4- Zone Descriptor Programming (LCD keypads only)
2 PROGRAMMING REVIEW MODE (no changes can be made)
3 submodes:
1- System Options
2- Zone and Report Code Programming
4- Zone Descriptor Programming (LCD keypads only)
3 WALK TEST
4 SYSTEM LOG VIEW (LCD keypads only)
5 SYSTEM DEFAULT
6 CLEAR TAMPER FAULTS (if programmed)
8 UNATTENDED DOWNLOAD
9 ON-LINE DOWNLOADING
INSTALLER MODE 1 (INSTALLER KEYPAD PROGRAMMING)
Enters the installer into keypad programming mode, which has 3 submodes (see below). To exit, simply
press the [STAY] key and return to the prior panel status. To change between these submodes, press
[
✱
] + [BYPASS] + Submode No.