![FBII OMNI-400 EU Installation And Setup Manual Download Page 65](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062065.webp)
Section 6. System Programming
6-29
For L2 and L4, make selections from the table below (L2 = 1 & 3 keys; L4 = 7 & 9 keys).
L2/L4
Entry
Arm
Away
Arm
Stay
Pager
Alert/Trouble
0
1
✔
2
✔
3
✔
✔
4
✔
5
✔
✔
6
✔
✔
7
✔
✔
✔
Arm Away/Stay: Selects the arming mode that the designated
soft keys will activate. The soft keys will force-arm the system
and bypass zones that are not ready. When you are using the
ADEMCO Point ID reporting format and Arm Away or Arm
Stay is enabled, a PID code of 401 with a user number of 123 is
sent to the central station when the system is armed using the
Arm Away/Stay soft keys or (if used) the arm-only keyswitch
attached to terminal 16. Additionally, if a Close Report code has
been programmed (Submode 2, Question 21, Locations 1 and 2)
the programmed code will be sent.
Pager/Beeps Alert/Trouble: If selected, a message will be sent
to the pager when the designated soft key is pressed. This can be
used to send a “help me” message.
QUESTION 19 SOFT KEY FUNCTIONS FOR
✱
& # AND CRYSTAL ADJUST
L1 L2
L3 L4
✱
& # Keys
Crystal Adj*
*NOTE: We recommend that the Crystal Adjustment be performed using the Time Set procedures. We
do not recommend making L3 and L4 entries in the Installer Mode.
For L1, make selections from the table below.
Sounder Options
Relay Options
L1
Entry
Silent
Keypad
Burg. Bell
Temporal
No Relay
Mom. Secs
Mom. Min
Toggle
0
✔
✔
1
✔
✔
2
✔
✔
3
✔
✔
4
✔
✔
5
✔
✔
6
✔
✔
7
✔
✔
8
✔
✔
9
✔
✔
A
✔
✔
B
✔
✔
C
✔
✔
D
✔
✔
E
✔
✔
F
✔
✔