Chapter: 7
Section:
Page
7
PERIPHERAL COMMUNICATIONS
For example, if machine parameter P009 (baudrate) shows the following options:
P009 Baudrate
150
300
600
1200
2400
4800
9600
19200
The value corresponding to each option will be:
1 (150), 2 (300), 3 (600), 4 (1200), 5 (2400), 6 (4800), 7 (9600), 8 (19200)
The end-of-line character will be the one indicated in the general machine
parameter P010.
Parameters for the axes Parameter number - Value - End-of-line character.
At least one blank space must be used as field separator.
The parameter number must consist of the letter “P” followed by 3 digits.
Example: P201
The parameter value will depend on the type of parameter.
*
Axis identification parameter.
It will be indicated by the letter or letters associated to it. Examples: P100 X,
P200 Y
A
, P300 Z
1
.
*
Parameters associated to position values.
This type of parameters are the ones associated to the display or feedback
resolution, the scaling factor and to the travel limits.
It will be indicated by the value assigned to the parameter. This value can
consist of the sign (-), up to 5 digits (4 in inches) to the left of decimal point,
the decimal point and up to 4 decimals (5 in inches). For example, for a
scaling factor = 1, write. P114 1.000
*
Leadscrew error compensation parameters.
It will be indicated by the value assigned to the error position and the error
value. It must be preceded by the characters “E =”.
The position and error values can consist of the sign (-), up to 5 digits (4 in
inches) to the left of decimal point, the decimal point and up to 4 decimals (5
in inches). Example: P117 -12.3400 E = 0.0020 in mm.
RECEIVE AND SEND
MACHINE PARAMETERS
Summary of Contents for VNP400
Page 1: ...FAGOR VNP400 Ref 9506 in...