Table 83: SNTP Source Interface Configuration Fields (continued)
Field
Description
Loopback Interface
When the selected Type is Loopback, select the loopback interface to use as the source
interface.
VLAN ID
When the selected Type is VLAN, select the VLAN to use as the source interface. The
menu contains only the VLAN IDs for VLAN routing interfaces.
Tunnel ID
When the selected Type is Tunnel, select the tunnel interface to use as the source
interface.
Click
Refresh
to display the latest information from the switch.
If you change any of the parameters, click
Submit
to apply the changes to the system. If you want the
switch to retain the new values across a power cycle, you must save the configuration.
Configuring Time Ranges
You can use these pages to configure time ranges to use in time-based
rules.
Time-based ACLs allow one or more rules within an ACL to be based on a periodic or absolute time.
Each ACL rule within an ACL except for the implicit deny all rule can be configured to be active and
operational only during a specific time period. The time range pages allow you to define specific times
of the day and week in order to implement time-based ACLs. The time range is identified by a name
and can then be referenced by an ACL rule defined within an ACL.
Time Range Configuration
Use the Time Range Configuration page to create a named time range. Each time range can consist of
one absolute time entry and/or one or more periodic time entries.
To access this page, click
System
>
Advanced Configuration
>
Time Ranges
>
Configuration
in the
navigation menu.
Table 84: Time Range Configuration
Field
Description
Time Range Name
The unique ID or name that identifies this time range. A time-based
reference the name configured in this field.
Time Range Status
Shows whether the time range is Active or Inactive. A time range is Inactive if the
current day and time do not fall within any time range entries configured for the
time range.
Periodic Entry Count
The number of periodic time range entries currently configured for the time
range.
Absolute Entry
Shows whether an absolute time entry is currently configured for the time range.
Use the buttons to perform the following tasks:
•
To add a time range, click
Add
and configure a name for the time range configuration.
•
To delete a configured time range, select each entry to delete, click
Remove
, and confirm the action.
•
Use
Submit
to add a new time range.
Configuring System Information
ExtremeSwitching 200 Series: Administration Guide
103