Dok-ID:EXPERT-0003-EN-2011
65
Pos : 6. 16 /SmartT urn/SmartTur n-Neu-02. 2011/ 6. 3. 8 I nt erne Ger ät ef ehl er @ 3\ mod_1297949053644_38. doc @ 26423
6.3.8 Internal device fault (secure state)
Possible causes
Measures
SmartTurn
control unit defective
Replace
SmartTurn
control unit.
Apply S1, S3 – settings.
Reverse mode
:
Turn drive roller (position encoder) a min. 45
degrees outside of the 0-position in the
movement range between the positions "Front"
and "Back"
Continuous mode – special mode
:
None
Reset fault
NOTE!
Eliminate cause.
Unscrew the cover on the turntable control unit.
Press the reset button for at least 3 s.
System fault LED goes out.
Turn the turntable several times at operating speed.
Press the reset button and the default values will be used for
turntable control.
NOTE!
Comply with the supplemental instructions in the
section ->
Commissioning
NOTE!
Press the reset button and the default values will
be used for turntable control.
Pos : 6.17 /Standar dmodule/8 Störungen/8.3 Inbetri ebnahme nach behobener Stör ung @ 0\mod_1193730477337_38.doc @ 1247