Turntable control SmartTurn
Structure and function
Dok-ID:EXPERT-0003-EN-2011
17
4.2.1 Standard mode
In standard mode, continuous operation and reverse operation are
differentiated.
Continuous mode
NOTE!
In normal operation the turntable only turns
forward. The turntable controller cycles the
turntable one clock cycle further with each
"Forward on" activation.
The "Reverse on" activation should only be
possible in jog mode in the PLC.
With "Reverse on" activation in continuous mode
there is no switch off of the turntable movement
through the turntable controller.
Necessary settings – continuous mode:
Securely connect input E4 to 24 V DC.
Set lock angle on switch S1 to setting 1 - 4 in accordance with
EXPERT specification, see chap. 4.2.7.
Pos : 4. 5 / Smart Tur n/SmartT urn-N eu- 02.2011/4. 2 - b R evesier betrieb @ 2\ mod_1296744168196_38. doc @ 25856
Reverse mode
NOTE!
The turntable turns forward/backward between
2 positions (usually 180 degrees). The turntable
controller cycles the turntable into the other
position.
Necessary settings – reverse mode:
Securely connect input E4 to 0 VDC.
Set lock angle on switch S1 to setting 1 - 4 in accordance with
EXPERT specification, see chap. 4.2.7.
Pos : 4. 6 / Smart Tur n/SmartT urn-N eu- 02.2011/4. 2.- c Sonder betri eb @ 2\ mod_1296744573995_38.doc @ 25873