![Expert SmartTurn Installation And Operating Instructions Manual Download Page 58](http://html1.mh-extra.com/html/expert/smartturn/smartturn_installation-and-operating-instructions-manual_2451828058.webp)
Turntable control SmartTurn
Faults
58
Dok-ID:EXPERT-0003-EN-2011
6.3.1 Sensor fault (sensor defect)
Possible causes
Measures
Sensor is defective
Check sensor and replace if necessary
Position encoder is defective or is not in the
detection range of the sensor
Check the position sensor, replace if necessary
Sensor cable is defective or loose
Check the position sensor, replace if necessary
Sensor cable has been inadvertently unscrewed
Screw on the sensor cable
Reset fault
NOTE!
Eliminate cause.
Unscrew the cover on the turntable control unit.
Press the reset button for at least 3 s.
System fault LED goes out.
Turn the turntable several times at operating speed.
Press the reset button and the default values will be used for
turntable control.
Pos : 6. 10 /SmartT urn/SmartTur n-Neu-02. 2011/ 6. 3. 3 Kurzsc hl uss am ausgang @ 3\ mod_1315561035885_38. doc @ 30187