Turntable control SmartTurn
Structure and function
Dok-ID:EXPERT-0003-EN-2011
15
Pos : 4. 2 / Smart Tur n/SmartT urn-N eu- 02.2011/4. 1. 1 Ger ät ebesc hr eibung @ 2\ mod_1296729895005_38. doc @ 25805
4.1.1 Device description
Sensor, Fig. 1
The sensor is equipped with:
A connection for the control unit.
One green LED and two yellow LEDs.
All three LEDs are illuminated when the sensor is connected to the
control unit.
Control unit, Fig. 2
The controller is equipped with:
Four connections for 24 V supply and PLC signals (X1), power
unit (X2), sensor (X3), diagnostics connection (X4).
Eight LEDs that enable fast and easy diagnosis. Faults are
indicated through flashing red LEDs. More information about
faults is provided in the
section -> Faults
.
LED
Function
Color
H1
System fault
Red
H2
Overrun forward
Red
H3
0-position
Yellow
H4
Overrun backward
Red
H5
End lock angle
Red
H6
Start forward on
Yellow
H7
Start backward on
Yellow
H8
Not assigned
-
H9
24 V power supply
Green
More extensive diagnoses is possible with the diagnostics
software, via the diagnostics connection (X4).