Turntable control SmartTurn
Faults
Dok-ID:EXPERT-0003-EN-2011
59
6.3.2 Short circuit at output
Possible causes
Measures
Activated contactor coil defective
Check the contactor coil, replace if necessary
Excessive power consumption of the activated
contactor coil
Only use contactor coils with a max. power
consumption of 14 W at 24 V DC
Contactor coil without protective circuit
Always wire contactor coils with Varistor protective
circuit
Short circuit due to wiring fault
Check wiring and change
Reset fault
NOTE!
Eliminate cause.
Unscrew the cover on the turntable control unit.
Press the reset button for at least 3 s.
System fault LED goes out.
Turn the turntable several times at operating speed.
Press the reset button and the default values will be used for
turntable control.