Turntable control SmartTurn
Installation and commissioning
36
Dok-ID:EXPERT-0003-EN-2011
CAUTION!
Damage to drive elements at operating speed!
Material damage can occur on the drive elements!
Therefore:
– Do not start the turntable from a non-defined
position.
E4 – operating mode (pin7)
The input must be permanently wired with 24 V or 0 V.
24 V must be applied on the input if the turntable will be operated
in continuous mode.
0 V must be applied on the input if the turntable will be operated in
reverse mode or special mode.
The mode of the turntable is communicated with the signal and
appropriate checks are activated.
E5 – pre-select cycles bit 1 (only special mode) (pin 16)
See table for function.
E6 – pre-select cycles bit 2 (only special mode) (pin 18)
See table for function.
Functions of E5 and E6 is special mode.
E5
E6
Functions
0 V
0 V
Turn 1 cycle
24V
0 V
Turn 2 cycles
0 V
24V
Turn 3 cycles*
24V
24V
Turn 4 cycles*
* Functions in preparation
In reverse mode and continuous mode inputs E5 and E6 have no
function.