Turntable control SmartTurn
Installation and commissioning
Dok-ID:EXPERT-0003-EN-2011
49
5.4
Commissioning
NOTE!
The turntable is commissioned in the factory by
EXPERT-TÜNKERS.
When the turntable is commissioned it is tested and the mode is
adjusted to customer specifications in reverse mode, continuous
mode or special mode.
When the operating voltage on the turntable is switched on,
simultaneously input E4 must be connected with 0 V for reverse
mode and special mode, or with 24 V for continuous mode.
Subsequent level change is not permissible and results in a system
fault.
Another commissioning process is only necessary when:
The control unit is replaced,
The mode is changed
or a system fault makes this necessary.
NOTE!
See section ->
System faults.
All data is saved in the control unit, failsafe. With the
commissioning process a default value specific to the lock
movement is used as switch-off angle. Thereafter deviation from
the optimal 0-position is determined and the switch-off angle is
determined for the next turn.