3GS Technical Manual
Issue 4.5 August 2005
8-68 Programming Menus
•
Door/security barrier control
The Controller, RKD, and I/O module relays are normally OFF (de-energised) – that is, when the output is turned ON, the
relay is energised (except for Controller relay 1 which is
fail safe
and therefore normally ON, power removed, output OFF).
For this reason, output1 is Intruder Alarm and is used as the primary alarm indicator.
You can duplicate outputs in order to assign any number of I/O module relays the same number, in which case they will
respond identically.
For example, output 2 drives the 3GS Controller on-board relay to activate the external sounder and an I/O node output
could also be programmed as output 2 to trigger external security lights when the sounder operates. You assign outputs using
the Node Configure menu – see “Nodes Configure - Outputs” on page 8-32 for further information.
Note
How an output operates is defined by the function assigned to it. More than one relay can be assigned to the same output
( i.e. more than one relay can be assigned to the same function)
Note
For the DM1200 to initiate communications on activation of output 1, the unit must be programmed to view
this as a negative trigger. To do this, change the output trigger control from POS to NEG. See also DM1200 in 3GS
Peripherals.
Power Consumption
When a 1A relay energises, it can typically draw up to 30mA. It is important that you take into consideration this power
consumption when calculating PSU requirements, particularly if a 6-output node is in use where the current drawn by the
relays alone may exceed 180mA. Output devices such as sounders/strobes and so on will also be drawing large amounts of
current. Remote power supply units should be used to power I/O nodes in such a situation.
Output functions
Output types range from 1 to 255 with their pre-defined functions as shown below. Output functions range from 1 to 1000.
The 255 output types may be mapped to any of the 1000 output functions depending on the system requirements – see “Edit
Output Database” on page 8-84. The system allows for spare output types with no pre-defined function. For example: 110,
174, 175.
The 3GS Controller has 4 on-board 1Amp relays, defaulted to types 1, 2, 3, and 4, while relays on the Nodes are not
defaulted and can be addressed to any of 255 output numbers.
1. To assign Output functions to Output Types, the Edit Output Database programming option is used – see “Edit Output
Database” on page 8-84.
2. To assign Output types to Physical Outputs (Relays), the Node Configure - Outputs menu is used - see “Node Configure”
on page 8-26
Summary of Contents for 3GS
Page 4: ...Introduction iv...
Page 12: ...Introduction 8...
Page 14: ...1...
Page 18: ...System Overview 1 6...
Page 20: ......
Page 26: ......
Page 34: ......
Page 38: ...Intelligent PSUs 4 6...
Page 40: ......
Page 97: ...Issue 4 5 August 2005 Nodes 5 59...
Page 98: ...Issue 4 5 August 2005 Nodes 5 61...
Page 100: ......
Page 106: ...3GS Technical Manual...
Page 116: ...3GS Technical Manual 7 12 Programming Overview Issue 4 5 August 2005 3GS Initial Setup Menu...
Page 118: ...3GS Technical Manual...
Page 146: ...3GS Technical Manual Issue 4 5 August 2005 Programming Menus 8 31 Node Configure Inputs Menu...
Page 153: ...3GS Technical Manual Issue 4 5 August 2005 8 38 Programming Menus Service Mode Test Menu...
Page 155: ...3GS Technical Manual Issue 4 5 August 2005 8 40 Programming Menus Service Mode Monitor Menu...
Page 217: ...3GS Technical Manual Issue 4 5 August 2005 8 108 Programming Menus...
Page 218: ...3GS Technical Manual Issue 4 5 August 2005 Programming Menus 8 109...
Page 220: ......
Page 222: ...3GS Version 5 User Guide 9 5 3GS SYSTEM KEYPAD DISPLAY...
Page 254: ...3GS Version 5 User Guide 9 37 Some examples of Alert Messages...
Page 264: ......
Page 265: ...I n t h i s c h a p t e r HHT Overview 10 3 Main Menu 10 5 HAND HELD TERMINAL HHT 10...
Page 266: ......
Page 280: ......
Page 288: ......
Page 290: ......
Page 293: ...Issue 4 5 August 2005 DM1200 Digital Communicator Modem 12 5...
Page 302: ......
Page 304: ...Network Router 13 4 SAMPLE CONNECTION DIAGRAM SCENARIOS...
Page 308: ...Network Router 13 8...
Page 310: ......
Page 318: ......
Page 338: ...Issue 4 5 August 2005 Technical Specifications 15 23...
Page 340: ...1...
Page 346: ......
Page 366: ...17 22...
Page 367: ...I n t h i s c h a p t e r Introduction to CiTeC II 18 3 CITEC II INSTALLATION 18...
Page 368: ......
Page 370: ...CiTeC II Installation 18 4...
Page 377: ...Issue 4 5 August 2005 19 7...
Page 378: ...19 8...
Page 385: ......
Page 386: ......