70
Expression Show Control System
Modifying fade and wait times
If you do not assign fade and wait times to a part, the
PSC automatically assigns
it the default fade times. No wait time will be recorded. Follow these steps to
assign fade and wait times to parts in a multipart cue:
1.
Press [Blind]. The
PSC displays the Blind mode screen.
2.
Enter the cue number.
3.
Press [Step/Part]; then enter the part number or press [+] or [-] until the
part you want to edit is displayed.
4.
Press [Time].
5.
Enter an upfade time in minutes and seconds or in seconds and frames
(00.00), then press [Enter]. Upfade times can be from 00.01 (one frame) to
99:59 (99 minutes; 59 seconds).
Note: Enter a decimal point between seconds and frames. (One second
equals thirty frames.)
6.
Enter an upfade wait time, and press [Enter]. (Upfade wait time is the
length of time after the multipart cue starts before the upfade.) If you do
not enter an upfade wait time, the
PSC assumes you want an upfade wait
time of zero.
7.
Enter a downfade wait time, and press [Enter]. Downfade wait time is the
length of time after the multipart cue starts before the downfade begins. If
you do not enter a downfade wait time, the
PSC assumes you want an
downfade wait time of zero.