98
Expression Show Control System
Deleting a step
Press [Step/Part], and enter the step number
. Then press [Clear]. The PSC
deletes the selected step and renumbers the remaining steps.
Inserting a step
Press [Step/Part], and enter the step number where you want to insert the new
step
. Press [Step/Part] again. The PSC inserts a blank step before the selected
step.
Subroutine keystrokes
Key
Action
[Blind]
Displays Blind mode screen.
[Cue]
Selects cue number.
[7]
Enters cue number.
[Type]
Displays fade type menu.
[4]
Select subroutine fade type.
[Cue Select]
Indicates next number entered will be cue number.
[1] [Enter]
Enters cue 1.
[3] [Enter]
Enters 3 second upfade.
[Enter]
Accepts 3 second downfade.
[5] [Enter]
Enters 5 second delay time before second cue begins.
[Cue Select]
Indicates next number entered will be cue number.
[2] [Enter]
Enters cue 2.
[At] [7] [5]
Enters 75 percent intensity level for cue.
[1] [Enter]
Enters 1 second upfade time.
[4] [Enter]
Enters 4 second downfade time.
[1] [0] [Enter]
Enters 10 second delay time.
[Cue Select]
Indicates next number entered will be cue number.
[3] [Enter]
Enters cue 3.
[At] [5] [0]
Enters 50 percent intensity level for cue.