4.8.2 Instructions
The instructions below detail how to set up the programmer to be powered at +5.0V from the Target
System.
1. Create a Programming Project which does NOT power the Target System
•
In EQTools – Project Builder – Select the <Target Power Supply Settings> tab
•
Set the ‘Target Voltage’ to +5.0V with a tolerance of +/- 500mV.
•
Set the ‘Programmer Controlled Power Supply’ to
<Programmer controlled Target
Power Supply: OFF>
•
Leave all other settings as the default values.
2. Connect the programmer to the Target System
•
Connect the Target System to the programmer via an ISP Cable, Fast Connect connectors
or wire-wrap connectors.
•
Remove
the
‘Vcc Option Link’
on the I/O Connector Module (labelled J6 or J28).
•
Check that you have a zero ohm connection between the
Target Vcc
(Vout) of the
programmer and the Vcc line of the Target System.
•
Using a DVM, check that there are no shorts between the
Target_Vcc
and Target Ground
3. Typical programming iteration
•
Power up the Target System
Æ
the programmer powers up
•
Using the keypad / display, select the required Programming Project
•
Press
<Yes>
key to execute Programming Project
•
Power down the programmer / Target System