PPM3 MKII Programmer - User Guide - V1.04 - 10
th
May 2008
7
1.4 Special Function Modules (SFM)
1.4.1 SFM Module - Overview
The PPM3-MK2 programmer features an interchangeable
‘Special Function Module’
. This module
contains all the
‘I/O Driver Circuitry’
which interfaces the programmer to the Target System. In the
event of damage to the programmer driver circuitry, it is possible to remove the complete Special
Function Module and replace it with a new one. This allows the programmer to be repaired in-situ
without the need to send it back to Equinox thereby saving valuable lost production time.
•
The PPM3-MK2 is fitted with the ‘EQ-SFM-1’ module as standard.
•
There are also other SFM modules available which offer faster SPI / JTAG speeds and better
ESD / Over-voltage protection.
1.4.2 SFM Module – Selection Guide
The SFM Modules which are currently available are listed in the table below:
Order Code
Description
EQ-SFM-1
Standard Special Function Module V1.0
•
Fitted to all PPM3-MK2 programmers as standard
•
Supports JTAG speeds up to approx 900 kHz
•
Supports SPI speeds up to approx 500 kHz
•
Limited ESD and over-voltage protection
•
Not recommended for driving capacitive or inductive loads
•
Not recommended if the Target System power is not supplied /
controlled from the programmer.
EQ-SFM-MAX-1.2 High-speed
High Current SFM Module V1.2
•
Supports JTAG speeds up to approx 1.3 MHz
•
Supports SPI speeds up to approx 4 MHz
•
Enhanced ESD protection
•
Enhanced over-voltage / fault protection
•
Safe to use when Target System is independently powered
•
Better at driving capacitive or inductive loads
•
Requires programmer firmware 3.04 or above
EQ-SFM-MAX-1.3
High-speed High Current SFM Module with 32kHz Oscillator V1.3
•
Supports JTAG speeds up to approx 1.3 MHz
•
Supports SPI speeds up to approx 4 MHz
•
Integrated 32 kHz Oscillator for performing accurate calibration of
Atmel AVR on-chip oscillators (replaces the CALCON module)
•
Enhanced ESD protection
•
Enhanced over-voltage / fault protection
•
Safe to use when Target System is independently powered
•
Better at driving capacitive or inductive loads
•
Requires programmer firmware 3.04 or above