PPM3 MKII Programmer
- User Guide - V1.04 - 10
th
May 2008
64
4.7 Programmer Powers the Target System
4.7.1 Overview
The PPM3 programmer is capable of supplying a controlled voltage from 3.0 to 5.0V to power the
Target System at a maximum current of 300mA. This allows the programmer to power the Target
System via the ISP Cable and switch power on / off under Programming Project / Script control. The
voltage and current settings must be set up in the Programming Project prior to powering up the
Target System. In this mode it is also possible for the programmer to automatically sense whether a
Target System is connected to the programmer – see Target Sensing section.
Fig. 4.7.1 Programmer powering the Target System
fig. 4.7.2 Settings for the programmer powering the Target System
#
Parameter
Description
1 Programmer
Input voltage
source
•
External 9.0 – 12.0 V DC regulated supply required
•
Connect power supply to either DC Jack Socket or 2-way Molex Power
Connector on the rear panel of the programmer.
2 V_Target
(Output voltage
to Target
System)
•
Programmer outputs a Controlled Voltage to the Target System:
3.0 – 5.0V DC @ 300mA max
•
Voltage / current setting must be set up in the Programming Project
3 Vcc
Option
Link
•
Not
Fitted
4 LK1
Link
•
Fitted
•
Programmer Vcc signal should be connected to the Target Vcc
5 Programmer
I/O Level
Converters
•
Programmer I/O Level Converter is powered at the Controlled Voltage
which is the same as the Target System voltage.
Summary of Contents for PPM3 MK2
Page 1: ...User Guide...