Maintenance Mode 2
56
o
Initialize NVRAM, timer, life counter, mechanical counter
Selecting this mode allows the user to initialize the NVRAM, timer, life counter,
and mechanical counter.
o
Initialize NVRAM
Selecting this mode allows the user to initialize the NVRAM.
o
Initialize RTC
Selecting this mode allows the user to set RTC initialized time to NVRAM.
The panel display is following;
RTC INIT = <YY>/<MM>/<DD>/<HH>
*<YY>: year, <MM>: month, <DD>: day, <HH>: hour
The cursor shifts "year ? month? day? hour?" with Cleaning button.
Time is adjusted with Paper feed "+" or "-" button.
RTC initialized time is set to NVRAM with Enter button, and RTC is initialized.
"RTC backup battery end" maintenance call is reset when RTC is initialized.
o
Initialize CR motor life
Selecting this mode allows the user to initialize the CR motor life counter.
o
Initialize CR motor life total
Selecting this mode allows the user to initialize the CR motor life total counter.
o
Initialize PF motor life
Selecting this mode allows the user to initialize the PF motor life counter.
o
Initialize head unit life
Selecting this mode allows the user to initialize the head unit life counter.
o
Initialize cleaning unit life
Selecting this mode allows the user to initialize the cleaning unit life counter.
o
Initialize total prints
Selecting this mode allows the user to initialize the total printed page counter.
o
Initialize ink capacity
Selecting this mode allows the user to initialize the ink capacity counter.
o
Initialize waste ink capacity
Selecting this mode allows the user to initialize the waste ink capacity counter.
o
NVRAM counter value indication
Selecting this mode allows the user to indicate each life counter in decimal.
o
CSIC detection level
Selecting this mode allows the user to adjust CSIC detection level. Each
adjustment value indicates as following;
ED MODE=X : It acquires information from CSIC and informs user of it.
ED MODE=N : It detects Japanese/overseas cartridge and doesn’t inform users of
it.
ED MODE=O : It acquires information from CSIC and doesn’t inform user of it at
all.
o
Failed nozzle limit (Dye/Pigment)
In case of nozzle check error with auto nozzle check, nozzle check error dose not occur
until it meet following condition permitting optional number of nozzle clogging.
This setting applies to all of nozzle check.
o
Ink cartridge type
It sets printer model (Dye/Pigment).
n
NPD = 0 : Neutral
n
NPD = 1 : Pigment type
n
NPD = 2 : Dye type
o
Selectable M/W 1, 2
Set the most suitable value of irregular M/W for each printer, and banding will
decrease.
There are 6 types for 720x720dpi FOL and 2 types for 1440x720dpi 4 pass.
o
MW7 balance
Adjust MW7 feeding in mode B when printing.
MW feeding per pass is defined as following;
N pass --- 1/7 d x unit
N+1pass --- 349/720inch -d x unit
Ink cartridge type
NPD
0,1,2
Selectable M/W (720x720FOL)
MW1 SELECT
1, 2, 3, 4, 5, 6, 7
Selectable M/W (1440x720FOL)
MW2 SELECT
1, 2
M/W7 balance adjustment
MW7 BALANCE
-30 ~ 0 ~ +30
Table 1-41. Maintenance mode 2 setup items
Item
Panel display
Setup value
Summary of Contents for Stylus Pro 10000 Series
Page 7: ...Revision Status ...
Page 8: ...Revision Issued Date Description Rev A March 30 2001 First Release ...
Page 13: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 59: ...EPSON Stylus Pro 10000 10000CF Revision B Product Description Jumper Settings 59 ...
Page 60: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 86: ...C H A P T E R TROUBLESHOOTING ...
Page 113: ...C H A P T E R DISASSEMBLY ASSEMBLY ...
Page 187: ...C H A P T E R ADJUSTMENT ...
Page 276: ...C H A P T E R MAINTENANCE ...
Page 289: ...C H A P T E R APPENDIX ...
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......
Page 319: ......
Page 320: ......
Page 321: ......
Page 322: ......
Page 323: ......