EPSON Stylus Pro 10000/10000CF
Revision B
Adjustment
Self-Diagnostics
263
o
[H to Cut] is the distance between the LC#1 to the cutter.
o
[E to H] is the distance between the edge sensor to the LC#1 head.
o
[R to H] is the distance between the rear sensor to the LC#1.
o
When the [Pause] key is pushed with the [Does update parameter?] display screen,
display moves to [Update: Ink parameter].
6.
Ink parameter
Update the ink parameter.
Following figure showing the ink parameter update menu sequence.
Figure 5-95.
o
When the [Pause] key is pushed with the [Does update parameter?] display screen,
display moves to [Update: Cap position].
Enter
Enter
Init. Fill : Set
Init. Fill : Reset
Update Parameter?
Updating Parameter?