EPSON Stylus Pro 10000/10000CF
Revision A
Disassembly & assembly
Disassembly Flow
182
8.
Remove two screws ( M1.2x8) securing Paper_Front Sensor to the bracket then
separate it.
Figure 4-164.
9.
Release the harness for the Paper_Front Sensor ASSY from the cable clamps then
remove it.
Figure 4-165.
NOTE: Paper_Front Sensor ASSY position is adjusted at factory. Therefore, be
sure to mark its current position before removing the screws.
Figure 4-166.
Screw
Specer
P_FRONT sensor
A D J U S T M E N T
R E Q U I R E D
If you replace the Paper_Front Sensor ASSY, perform the necessary
adjustment listed in Chapter 5.
C A U T I O N
When assembly, 2 places of bosses are combined.
Screw
Spring
Paper_Front sensor