Disassembly & assembly
Disassembly Flow
170
4.2.3.12 Removing Flushing Box
1.
Pull out three waste ink tubes from tube clump.
2.
Disconnect the connector of the fan cable, that is jointed to connector CN35 on the
C362DRV board in the joint adapter department of the R side frame.
3.
Remove two screws (: M4x8) fixing the flushing box, then shift the flushing box to the
left a little.
Figure 4-131.
4.
Remove the waste ink tube from the tube clamp on the waste ink unit, then remove the
flushing box with the waste ink tube.
Figure 4-132.
Clump
Flushing box
Screw
Screw
Cable connector
Waste ink tube
Waste ink unit
Tube clump
C A U T I O N
When remove the waste ink tube, do the measure so as not to get dirty
with the rag etc. because there is the possibility that the remaining ink
leaks.