EPSON Stylus Pro 10000/10000CF
Revision B
Adjustment
Adjustment Steps
202
Figure 5-11. VR layout
6.
Confirm the value with sheet set is within the ON value (Right value).
EDGE SENSOR
1.
Remove the rear cover.
2.
Set the adjustment sheet normally. (Refer to Table 5-4, “Test sheet and Adjustable
VR,” on page 201.)
3.
Enter the Self-diagnostic mode. (Refer to “Start-up procedure” on page 213.)
4.
Select "Test"/"Sensor"/"EdgeAD" by panel operation. (Refer to “Sensor” on
page 217.)
5.
Take the carriage and move on the paper manually.
6.
Adjusting VR 3 or VR6 (Refer to “VR layout” on page 202.) , the ON-value (Right
value) becomes within the adjustment range. (Refer to Table 5-5, “Adjustment
Range,” on page 202.)
7.
Confirm the value with sheet set is within the ON-OFF value (Left value).
Table 5-5. Adjustment Range
Sensor
Left (ON-OFF)
Right (ON)
P_Front
040 - 04A
040 - 05E
P_Rear
040 - 04A
040 - 05E
P_Edge
0B0 - 0CF
0C0 - 0CF
VR5
VR4
VR2
VR3
VR6
VR1
Summary of Contents for Stylus Pro 10000 Series
Page 7: ...Revision Status ...
Page 8: ...Revision Issued Date Description Rev A March 30 2001 First Release ...
Page 13: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 59: ...EPSON Stylus Pro 10000 10000CF Revision B Product Description Jumper Settings 59 ...
Page 60: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 86: ...C H A P T E R TROUBLESHOOTING ...
Page 113: ...C H A P T E R DISASSEMBLY ASSEMBLY ...
Page 187: ...C H A P T E R ADJUSTMENT ...
Page 276: ...C H A P T E R MAINTENANCE ...
Page 289: ...C H A P T E R APPENDIX ...
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......
Page 319: ......
Page 320: ......
Page 321: ......
Page 322: ......
Page 323: ......