EPSON Stylus Pro 10000/10000CF
Revision A
Disassembly & assembly
Disassembly Flow
154
8.
Remove two screws (CP M3x6 )fixing the Damper holder.
Figure 4-89.
9.
Remove two screws (CP M4x6 )fixing the Damper holder.
Figure 4-90.
10. Remove the damper holder with the cable and tube.
Figure 4-91.
11. Remove screw fixing the earth plate. Do not drop the nut of the reverse side.
Figure 4-92.
damper holder
Screw
Screw
C A U T I O N
When assembly, do not mistake the attachment location of the tube
and pipe.
Do not insert the tube pipe with the damper holder.
Do not mistake the attachment
location of the tube and pipe.
Do not insert the tube pipe
with the damper holder.
Nut
Screw