GX8 Manipulator 3. Environments and Installation
134
GX series Rev.2
3.6 User Wires and Pneumatic Tubes
CAUTION
■
Only authorized or certified personnel should be allowed to perform wiring. Wiring
by unauthorized or uncertified personnel may result in bodily injury and/or
malfunction of the robot system.
3.6.1 Electrical Wires
Connect the following connectors and cables to the user connector of the Manipulator.
Cable specifications in the Manipulator
Rated Voltage
Allowable Current
Nominal Sectional Area
Note
D-sub 15pin
D-sub 9pin
AC/DC30 V
0.6A
0.08 mm
2
With shield
RJ45
-
-
-
Equivalent to
CAT5e
Inside the Manipulator, pins with the same number are wired between the connector on the
base side and the connector on the Arm #2 side in the manipulator.
Recommended connector to connect to the Manipulator
Standard-model, ESD model, Cleanroom & ESD model
Model number
Standard
Manufacturer Note
D-sub
15 pin
Connector
61801524823
Solder type
Würth
Elektronik
×2
Clamp Hood
61801525311
Fitted setscrew:
#4-40 UNC
×2
D-sub
9 pin
Connector
61800924823
Solder type
×2
Clamp Hood
61800925311
Fitted setscrew:
#4-40 UNC
×2
RJ45
Connector
6-569550-3
-
CommScope
-
Protected-model
Model number
Standard
Manufacturer Note
D-sub
15 pin
Connector
09670155615
Solder type
HARTING
×2
Clamp hood
09670150538
Fitted setscrew:
#4-40 UNC
×2
D-sub
9 pin
Connector
09670095615
Solder type
×2
Clamp hood
09670090538
Fitted setscrew:
#4-40 UNC
×2
RJ45
Connector
09451951560
-
-