GX8 Manipulator 3. Environments and Installation
GX series Rev.2
135
3.6.2 Pneumatic Tubes
Pneumatic tube specifications in the Manipulator
For each connector, inside the Manipulator, fittings of the same size and tip color
(blue/white) are piped between the air fitting on the base side and the air fitting on the Arm
#2 side.
Recommended pneumatic tube to connect to the Manipulator
Outer diameter Model number
Manufacturer
Note
ø6mm
TU0604*
SMC
Equivalent products from
various manufactures can be
used.
ø4mm
TU0425*
When the Manipulator is a Protected-model, be aware of the followings.
CAUTION
■
Be sure to use IP65 compliant wires and tubes when using the Manipulator under
special environmental conditions (adverse condition with dust and oily smoke).
Wiring and piping with the except Protected-model may result in electric shock
and/or malfunction of the robot system as it cannot ensure IP65.
■
Be sure to attach the cap on the user cable connector when not using the
connector. Using the Manipulator without the cap may cause equipment damage
to and/or malfunction of the Manipulator as dust or oily smoke gets into the
connector.
Max. usable pneumatic pressure
Pneumatic
tubes
Outer diameter
×
Inner diameter
0.59Mpa (6 kgf/cm2 : 86 psi)
2
ø6mm
×
ø4 mm
2
ø4mm
×
ø2.5 mm
Summary of Contents for SCARA GX Series
Page 1: ...Original instructions Rev 2 EM221R5129F SCARA Robots GX series Manual ...
Page 2: ...GX series Manual Rev 2 ...
Page 12: ......
Page 86: ...GX4 Manipulator 5 Motion Range 76 GX series Rev 2 ...
Page 88: ......
Page 188: ......
Page 202: ......