Maintenance 8. Joint #4
LS10-B Rev.6
131
(10) Check if the Joint #4 moves in a Jog motion by operating from EPSON RC+ menu -
[Tools]-[Robot Manager]-[Jog & Teach].
If the Manipulator oscillates with MOTOR ON and the following errors are detected,
Error 5041: Motor torque output failure in low power state.
Error 4241: Over speed during low power mode was detected.
or when the joint other than Joint #4 moves, the connector for other joint might be
connected to the Joint #4 motor. Check the connector connection.
(11) Execute the calibration of Joint #4.
For details, refer to
Maintenance: 13. Calibration
.