5.1.1 Max. Pulse Range of Joint #1
The 0 (zero) pulse position of Joint #1 is the position where Arm #1 faces toward the positive
(+) direction on the X-coordinate axis.
When the 0 pulse is a starting point, the counterclockwise pulse value is defined as the
positive (+) and the clockwise pulse value is defined as the negative (
-
).
+Y
+X 0 pulse
+ B
−
B
+ A
−
A
A: Max. Motion Range
B: Max. Pulse Range
LS10-B
±
132
°
−
152918~808278 pulse
5.1.2 Max. Pulse Range of Joint #2
The 0 (zero) pulse position of Joint #2 is the position where Arm #2 is in-line with Arm #1.
With the 0 pulse as a starting point, the counterclockwise pulse value is defined as the
positive (+) and the clockwise pulse value is defined as the negative (
-
).
−
B
+ B
0 pulse
−
A
+ A
A: Max. Motion Range
B: Max. Pulse Range
LS10-B
±
150
°
±
341334 pulse