![Epson LS10-B User Manual Download Page 172](http://html.mh-extra.com/html/epson/ls10-b/ls10-b_user-manual_110798172.webp)
Maintenance 13. Calibration
160
LS10-B Rev.6
13.3 Accurate Calibration of Joint #2
When coordinates for the Manipulator working point require calculation, it is important for
Joint #2 to be calibrated accurately.
If the accuracy of Joint #2 is not obtained through the steps in the section
Maintenance: 13.2
Calibration Procedure
, follow the steps below “Calibration Using Right / Left Arm
Orientations” to accurately calibrate Joint #2.
The reference point is the center of the ball screw
spline shaft during this calibration.
When there is a misalignment between the center
of the end effector and the center of the ball screw
spline shaft, remove the end effector and execute
the calibration of the shaft.
The center of the shaft
There is a misalignment
between the center of
the end effector and the
center of the shaft.
Make a calibration jig as shown in the right figure
and attach it on the end of the shaft to make the
center of the shaft clear.
Decide a target point and mark a cross (
×
) on it
so that you can easily verify the center of the
shaft after switching the arm pose between right
and left.
Calibration jig at the
end of the shaft
(Example)
Target point
The center
of the shaft
After removing the end effector and executing the calibration, install the end effector and
move the Manipulator to the teaching point to verify whether there is a positional gap. If
there is a positional gap, fine-tune the installation position of the end effector and teach the
point again.
Coordinates for the working point requires calculation in the following cases:
· Teaching the working point by entering the coordinate values (MDI teaching)
· Switching the arm orientation between right and left at a given point
· Using the Pallet command
· Executing CP control (such as liner or circular interpolation)
· Using the Local command
· Pose data specified with relative coordinates <Example: P1+X(100) >
· Vision Guide camera calibrations
NOTE
Summary of Contents for LS10-B
Page 1: ...Rev 6 EM204R4257F SCARA ROBOT LS10 B series MANIPULATOR MANUAL ...
Page 2: ...MANIPULATOR MANUAL LS10 B series Rev 6 ...
Page 8: ...vi LS10 B Rev 6 ...
Page 12: ...TABLE OF CONTENTS x LS10 B Rev 6 ...
Page 14: ......
Page 25: ...Setup Operation 1 Safety LS10 B Rev 6 13 LS10 B Figure LS10 B702S ...
Page 65: ...Setup Operation 5 Motion Range LS10 B Rev 6 53 Standard model LS10 B S ...
Page 66: ...Setup Operation 5 Motion Range 54 LS10 B Rev 6 Cleanroom model LS10 B C ...
Page 68: ......
Page 89: ...Maintenance 4 Cable LS10 B Rev 6 77 4 2 Wiring Diagrams 4 2 1 Signal Cable ...
Page 90: ...Maintenance 4 Cable 78 LS10 B Rev 6 4 2 2 Power Cable ...