3.4
Instrument versions
By means of the order code on the nameplate
you can identify the instrument version,
and the required power supply.
pH and redox measuring transmitter Mycom CPM 152
Field housing for wall mounting, ingress protection IP 65
basic version with:
2 signal outputs 0 / 4 ... 20 mA (pH/redox and temperature),
2 output contacts, integrated electrode function monitoring
Equipment and certificate
1-circuit version for non-hazardous areas
A1A
Basic version
A1B
3 relays (Chemoclean)
A1C Feedback/hold contact
A1D 3 relays / feedback/hold contact (Autoclean)
A1E
PROFIBUS
A1F
3 relays (Chemoclean), PROFIBUS
A1G Feedback/hold contact, PROFIBUS
A1H 3 relays / feedback/hold contact (Autoclean), PROFIBUS
2-circuit version for non-hazardous areas
A2A
Basic version
A2B
3 relays (Chemoclean)
A2C Feedback/hold contact
A2D 3 relays / feedback/hold contact (Autoclean)
1-circuit version for Ex areas (CENELEC)
Z1A
Basic version, EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z1B
3 optocouplers (Chemoclean), EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z1C
Feedback/hold contact, EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z1D
3 optocouplers / feedback/hold contact (Autoclean), EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z1E
PROFIBUS, EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z1F
3 optocouplers (Chemoclean), PROFIBUS, EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z1G Feedback/hold contact, PROFIBUS, EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z1H
3 optocouplers / feedback/hold contact (Autoclean), PROFIBUS, EEx em [ia/ib] IIC T4, Atex II (1) 2G
2-circuit version for Ex areas (CENELEC)
Z2A
Basic version, EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z2B
3 optocouplers (Chemoclean), EEx em [ia/ib] IIC T4, Atex II (1) 2G
Z2C
Feedback/hold contact, EEx em [ia/ib] IIC T4, Atex II (1) 2G
1-circuit version for Ex areas (FM)
F1A
Basic version, NI outputs Cl. I Div. 2, Cl. II/III Div. 1, Cl. I Zone 2
F1B
3 optocouplers (Chemoclean), NI outputs Cl. I Div. 2, Cl. II/III Div. 1, Cl. I Zone 2
F1D
3 optocouplers / feedback/hold contact (Autoclean), EEx em [ia/ib] IIC T4, Atex II (1) 2G,
NI outputs Cl. I Div. 2, Cl. II/III Div. 1, Cl. I Zone 2
F1H
3 optocouplers / feedback/hold contact (Autoclean), PROFIBUS,
NI outputs Cl. I Div. 2, Cl. II/III Div. 1, Cl. I Zone 2
2-circuit version for Ex areas (FM)
F2B
3 optocouplers (Chemoclean), NI outputs Cl. I Div. 2, Cl. II/III Div. 1, Cl. I Zone 2
1-circuit version for Ex areas (FM AIS)
G1A Basic version, AIS NI Cl. I-III Div. 1&2, Group A-G
G1B 3 optocouplers (Chemoclean), AIS NI Cl. I-III Div. 1&2, Group A-G
G1D 3 optocouplers / feedback/hold contact (Autoclean), EEx em [ia/ib] IIC T4, Atex II (1) 2G,
AIS NI Cl. I-III Div. 1&2, Group A-G
G1H 3 optocouplers / feedback/hold contact (Autoclean), PROFIBUS,
AIS NI Cl. I-III Div. 1&2, Group A-G
2-circuit version for Ex areas (FM AIS)
G2B 3 optocouplers (Chemoclean), AIS NI Cl. I-III Div. 1&2, Group A-G
(p. t. o.)
pm152e03.chp
mycom CPM 152
Description
Hauser
5