Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range
2. The non-metallic label may store an electrostatic
charge and become a source of ignition in Group III
environments
3. Guard the LCD cover against impact energies greater
than 4 joules
4. Flameproof joints are not intended for repair.
5. A suitable certified Ex d or Ex tb enclosure is required to
be connected to temperature probes with Enclosure
option “N”.
6. Care shall be taken by the end user to ensure that the
external surface temperature on the equipment and
the neck of DIN Style Sensor probe does not exceed
130 °C.
7. Non-Standard Paint options may cause risk from
electrostatic discharge. Avoid installations that cause
electrostatic build-up on painted surfaces, and only
clean the painted surfaces with a damp cloth. If paint is
ordered through a special option code, contact the
manufacturer for more information.
B.5 International
E7
IECEx
Flameproof
Certificate: IECEx FMG 12.0022X
Standards: IEC 60079-0:2011, IEC 60079-1:2007-04,
IEC 60079-31:2008
Markings: Ex d IIC T6…T1 Gb, T6(–50 °C
≤
T
a
≤
+40 °C), T5…T1(–50 °C
≤
T
a
≤
+60 °C);
Ex tb IIIC T130 °C Db, (–40 °C
≤
T
a
≤
+70 °C); IP66
See
at the end of the Product Certifications
section for Process Temperatures.
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic
charge and become a source of ignition in Group III
environments.
3. Guard the LCD display cover against impact energies
greater than 4 joules.
4. Flameproof joints are not intended for repair.
5. A suitable certified Ex d or Ex tb enclosure is required to
be connected to temperature probes with Enclosure
option “N”.
6. Care shall be taken by the end user to ensure that the
external surface temperature on the equipment and
the neck of DIN Style Sensor probe does not exceed
130 °C.
7. Non-Standard Paint options may cause risk from
electrostatic discharge. Avoid installations that cause
electrostatic build-up on painted surfaces, and only
clean the painted surfaces with a damp cloth. If paint is
ordered through a special option code, contact the
manufacturer for more information.
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 07.0002X [HART];
IECEx BAS 07.0004X [Fieldbus]
Standards: IEC 60079-0: 2011; IEC 60079-11: 2011;
Markings: HART: Ex ia IIC T5/T6 Ga;
T6(–60 °C
≤
T
a
≤
+50 °C),
T5(–60 °C
≤
T
a
≤
+75 °C
Fieldbus: Ex ia IIC T4 Ga;
T4(-60 °C
≤
T
a
≤
+60 °C)
at the end of the Product Certifications
section for Entity Parameters.
Special Conditions for Safe Use (X):
1. When fitted with the transient terminal options, the
apparatus is not capable of withstanding the 500 V
electrical strength test as defined in Clause 6.3.13 of
IEC 60079-11: 2011. This must be taken into account
during installation.
2. The enclosure may be made from aluminum alloy with
a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion
when located in Zone 0.
N7
IECEx Type n
Certificate: IECEx BAS 070003X [HART];
IECEx BAS 07.0005X [Fieldbus]
Standards: IEC 60079-0:2011, IEC 60079-15:2010
Markings: HART: Ex nA IIC T5/T6 Gc;
T6(–40 °C
≤
T
a
≤
+50 °C),
T5(–40 °C
≤
T
a
≤
+75 °C)
Fieldbus: Ex nA IIC T5 Gc;
T5(–40 °C
≤
T
a
≤
+ 75 °C)
B.6 Brazil
E2
INMETRO Flameproof and Dust
Certificate: UL-BR 13.0535X
Standards: ABNT NBR IEC 60079-0:2008 +
corrigendum 1:2011, ABNT NBR IEC
60079-1:2009 + corrigendum 1:2011,
ABNT NBR IEC 60079-31:2011
Summary of Contents for Rosemount 3144P
Page 2: ......
Page 10: ...8 Reference Manual 00809 0100 4021 Rev JA Title Page April 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 4021 Rev JA Introduction April 2017 Introduction ...
Page 38: ...28 Reference Manual 00809 0100 4021 Rev JA Installation April 2017 Installation ...
Page 235: ...225 Reference Manual 00809 0100 4021 Rev JA April 2017 ...