156
Reference Manual
00809-0100-4021, Rev JA
Configuration
April 2017
Configuration
4.9.7
Analog input diagnostics
Table 4-9. AI BLOCK_ERR Conditions
Table 4-10. Troubleshooting the AI block
Condition
number
Condition name and description
0
Other
1
Block Configuration Error: the selected channel carries a measurement that is incompatible with
the engineering units selected in XD_SCALE, the L_TYPE parameter is not configured, or
CHANNEL = zero.
3
Simulate Active: Simulation is enabled and the block is using a simulated value in its execution.
7
Input Failure/Process Variable has Bad Status: The hardware is bad, or a bad status is being
simulated.
14
Power Up: Block is not scheduled.
15
Out of Service: The actual mode is out of service.
Symptom
Possible causes
Recommended actions
Bad or no temperature
readings
(Read the AI
“BLOCK_ERR”
parameter)
BLOCK_ERR reads OUT OF
SERVICE (OOS)
1. AI Block target mode target mode set to OOS.
2. Resource Block OUT OF SERVICE.
BLOCK_ERR reads
CONFIGURATION ERROR
1. Check CHANNEL parameter (see
2. Check L_TYPE parameter (see
3. Check XD_SCALE engineering units. (see
)
BLOCK_ERR reads POWERUP
Download schedule into block. Refer to host for downloading
procedure.
BLOCK_ERR reads BAD INPUT
1. Sensor Transducer Block Out Of Service (OOS)
2. Resource Block Out of Service (OOS)
No BLOCK_ERR but readings are
not correct. If using Indirect
mode, scaling could be wrong.
1. Check XD_SCALE parameter.
2. Check OUT_SCALE parameter.
“XD_SCALE and OUT_SCALE” on page 151
)
No BLOCK_ERR. Sensor needs to
be calibrated or Zero trimmed.
See
to determine the appropriate
trimming or calibration procedure.
OUT parameter status
reads UNCERTAIN and
substatus reads
EngUnitRangViolation.
Out_ScaleEU_0 and EU_100
settings are incorrect.
See
“XD_SCALE and OUT_SCALE” on page 151
.
Summary of Contents for Rosemount 3144P
Page 2: ......
Page 10: ...8 Reference Manual 00809 0100 4021 Rev JA Title Page April 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 4021 Rev JA Introduction April 2017 Introduction ...
Page 38: ...28 Reference Manual 00809 0100 4021 Rev JA Installation April 2017 Installation ...
Page 235: ...225 Reference Manual 00809 0100 4021 Rev JA April 2017 ...