Reference Manual
00809-0100-4021, Rev JA
HART Commissioning
April 2017
HART Commissioning
Ignore next 50 occurrences of status?
Asked after displaying device status. Softkey answer determines whether next 50
occurrences of device status will be ignored or displayed.
Illegal character
An invalid character for the variable type was entered.
Illegal date
The day portion of the date is invalid.
Illegal month
The month portion of the date is invalid.
Illegal year
The year portion of the date is invalid.
Incomplete exponent
The exponent of a scientific notation floating point variable is incomplete.
Incomplete field
The value entered is not complete for the variable type.
Looking for a device
Polling for multidropped devices at addresses 1–15.
Mark as read only variable on hotkey
menu?
Asks whether the user should be allowed to edit the variable from the hotkey menu if the
item being added to the hotkey menu is a variable.
No device configuration in
configuration memory
There is no configuration saved in memory available to re-configure off-line or transfer to
a device.
No device found
Poll of address zero fails to find a device, or poll of all addresses fails to find a device if
auto-poll is enabled.
No hotkey menu available for this
device.
There is no menu named “hotkey” defined in the device description for this device.
No offline devices available
There are no device descriptions available to be used to configure a device offline.
No simulation
devices available
There are no device descriptions available to simulate a device.
No UPLOAD_VARIABLES in ddl for this
device
There is no menu named “upload_variables” defined in the device description for this
device. This menu is required for offline configuration.
No valid items
The selected menu or edit display contains no valid items.
OFF KEY DISABLED
Appears when the user attempts to turn the Field Communicator off before sending
modified data or before completing a method.
Online device disconnected with unsent
data. RETRY or OK to lose data.
There is unsent data for a previously connected device. Press RETRY to send data, or press
OK to disconnect and lose unsent data.
Out of memory for hotkey
configuration. Delete unnecessary
items.
There is no more memory available to store additional hotkey items. Unnecessary items
should be deleted to make space available.
Overwrite existing configuration
memory
Requests permission to overwrite existing configuration either by a device-to-memory
transfer or by an offline configuration. User answers using the softkeys.
Press OK
Press the OK softkey. This message usually appears after an error message from the
application or as a result of HART communications.
Restore device value?
The edited value that was sent to a device was not properly implemented. Restoring the
device value returns the variable to its original value.
Save data from device to configuration
memory
Prompts user to press SAVE softkey to initiate a device-to-memory transfer.
Saving data to configuration memory
Data is being transferred from a device to configuration memory.
Sending data to device
Data is being transferred from configuration memory to a device.
There are write only variables which
have not been edited. Please edit them.
There are write-only variables that have not been set by the user. These variables should
be set or invalid values may be sent to the device.
Table 3-3. Field Communicator Error Warning Descriptions – HART
(1)
Message
Description
Summary of Contents for Rosemount 3144P
Page 2: ......
Page 10: ...8 Reference Manual 00809 0100 4021 Rev JA Title Page April 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 4021 Rev JA Introduction April 2017 Introduction ...
Page 38: ...28 Reference Manual 00809 0100 4021 Rev JA Installation April 2017 Installation ...
Page 235: ...225 Reference Manual 00809 0100 4021 Rev JA April 2017 ...