141
Reference Manual
00809-0100-4021, Rev JA
Configuration
April 2017
Configuration
MAINT_ACTIVE
The MAINT_ACTIVE parameter displays which of the alarms is active. Only the condition with the highest
priority will be displayed. This priority is not the same as the MAINT_PRI parameter described above. This
priority is hard coded within the device and is not user configurable.
MAINT_ALM
An alarm indicating the device needs maintenance soon. If the condition is ignored, the device will
eventually fail.
Advisory alarms
An advisory alarm indicates informative conditions that do not have a direct impact on the device's
primary functions. There are five parameters associated with ADVISE_ALARMS. They are described
below.
ADVISE_ENABLED
The ADVISE_ENABLED parameter contains a list of informative conditions that do not have a direct
impact on the device's primary functions. Below is a list of the advisories with the highest priority first.
1. NV writes deferred
2. SPM Process Anomaly detected
ADVISE_MASK
The ADVISE_MASK parameter will mask any of the failed conditions listed in ADVISE_ENABLED. A bit on
means the condition is masked from alarming and will not be reported.
ADVISE_PRI
ADVISE_PRI designates the alarming priority of the ADVISE_ALM, see
default is 0, and the recommended values are 1 or 2.
ADVISE_ACTIVE
The ADVISE_ACTIVE parameter displays the active advisories. Only the advisory with the highest priority
is displayed. This priority is not the same as the ADVISE_PRI parameter described above, but is hard
coded within the device and is not user configurable.
ADVISE_ALM
ADVISE_ALM indicates advisory alarms. These conditions do not have a direct impact on the process or
device integrity.
Summary of Contents for Rosemount 3144P
Page 2: ......
Page 10: ...8 Reference Manual 00809 0100 4021 Rev JA Title Page April 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 4021 Rev JA Introduction April 2017 Introduction ...
Page 38: ...28 Reference Manual 00809 0100 4021 Rev JA Installation April 2017 Installation ...
Page 235: ...225 Reference Manual 00809 0100 4021 Rev JA April 2017 ...