Specifications and Reference Data
Reference Manual
00809-0100-4021, Rev JA
Specifications and Reference Data
April 2017
179
Appendix A
Specifications and Reference Data
HART and Foundation Fieldbus specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 179
HART/4–20 mA specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 185
Foundation Fieldbus specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 186
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 189
Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 194
How to order Rosemount X-well Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 198
A.1 HART and F
OUNDATION
Fieldbus specifications
A.1.1 Functional specifications
Inputs
User-selectable. See
“Transmitter accuracy” on page 181
for sensor options.
Output
2-wire device with either 4–20 mA/HART
®
, linear with
temperature or input. Completely digital output with
F
OUNDATION
™
Fieldbus communication (ITK 4.5 compliant).
Isolation
Input/output isolation tested up to 500 Vrms (707 Vdc).
Humidity limits
0–99 percent relative humidity (non-condensing).
Update time
Approximately 0.5 seconds for a single sensor (one second
for dual sensors).
A.1.2 Physical specifications
Conduit connections
The standard field mount housing has
1
/
2
–14 NPT conduit
entries. Additional conduit entry types are available,
including PG13.5 (PG11), M20
1.5 (CM20), or JIS G
1
/
2
.
When any of these additional entry types are ordered,
adapters are placed in the standard field housing so these
alternative conduit types fit correctly. See
for dimensions.
Materials of construction
Electronics housing
low-copper aluminum or CF-8M (cast version of 316
stainless steel)
Paint
Polyurethane
Cover O-rings
Buna-N
Mounting
Transmitters may be attached directly to the sensor.
Optional mounting brackets (codes B4 and B5) permit
remote mounting. See
Optional Mounting Bracket” on page 191
.
Summary of Contents for Rosemount 3144P
Page 2: ......
Page 10: ...8 Reference Manual 00809 0100 4021 Rev JA Title Page April 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 4021 Rev JA Introduction April 2017 Introduction ...
Page 38: ...28 Reference Manual 00809 0100 4021 Rev JA Installation April 2017 Installation ...
Page 235: ...225 Reference Manual 00809 0100 4021 Rev JA April 2017 ...