Table 4-81. Discrete Input Function Block Parameter Definitions (Continued)
Label
PARAMETER_NAME
Description
Initial Value
Range
Block
Mode
RO /
RW
Index
Number
Block Alarm
BLOCK_ALM
19
Dynamic
Data Type: DS-72
The block alarm is used for all configuration,
hardware, connection failure, or system
problems in the block. The cause of the alert
is entered in the subcode field. The first alert
to become active will set the active status in
the status parameter. As soon as the
unreported status is cleared by the alert
reporting procedure, and other block alert
may be reported without clearing the active
status, if the subcode has changed.
UNACKNOWLEDGED
19.1
RW
N/A
0=Undefined
1=Acknowledged
2=Unacknowledged
ALARM_STATE
19.2
RO
N/A
0=Undefined
1=Clear reported
2=Clear not reported
3=Active reported
4=Active not reported
TIME_STAMP
19.3
RO
N/A
SUBCODE
19.4
RO
N/A
VALUE
19.5
RO
Alarm Summary
ALARM_SUM
20
0: Discrete alarm
7: Block Alarm
Data Type: DS-74
The current alert status, unacknowledged
states, unreported states, and disabled
states of the alarms associated with the
function block.
0=clear reported
0=acknowledged
0=reported
0=enabled
CURRENT
20.1
RO
All bits: 0
UNACKNOWLEDGED
20.2
RO
All bits: 0
UNREPORTED
20.3
RO
All bits: 0
DISABLED
20.4
RW
All bits: 0
Acknowledge Option
ACK_OPTION
21
ALL
0: Discrete
1: Block Alarm
All bits: 0
Data Type: Bit String
0=Disable
1=Enable
Used to set auto acknowledgement of alarms
Discrete Priority
DISC_PRI
22
ALL
0 to 15
0
Data Type: Unsigned8
Priority of the discrete alarm.
Discrete Limit
DISC_LIM
23
ALL
PV_STATE
0
Data Type: Unsigned8
State of discrete input which will generate an
alarm.
Discrete Alarm
DISC_ALM
24
Data Type: DS-72
The discrete alarm is used for indication of a
state change in selected discrete channel.
UNACKNOWLEDGED
24.1
RW
N/A
0=Undefined
1=Acknowledged
2=Unacknowledged
ALARM_STATE
24.2
RO
N/A
0=Undefined
1=Clear reported
2=Clear not reported
3=Active reported
4=Active not reported
TIME_STAMP
24.3
RO
N/A
SUBCODE
24.4
RO
N/A
VALUE
24.5
RO
N/A
4
Summary of Contents for FIELDVUE DVC6200f
Page 42: ...DVC6200f Digital Valve Controller November 2010 30 4 ...
Page 60: ...DVC6200f Digital Valve Controller November 2010 48 4 ...
Page 108: ...DVC6200f Digital Valve Controller November 2010 96 4 ...
Page 122: ...DVC6200f Digital Valve Controller November 2010 110 4 ...
Page 188: ...DVC6200f Digital Valve Controller November 2010 176 4 ...
Page 200: ...DVC6200f Digital Valve Controller November 2010 188 4 ...
Page 216: ...DVC6200f Digital Valve Controller November 2010 204 5 ...
Page 250: ...DVC6200f Digital Valve Controller November 2010 238 8 ...
Page 254: ...DVC6200f Digital Valve Controller November 2010 242 A ...
Page 284: ...DVC6200f Digital Valve Controller November 2010 272 D ...
Page 290: ...DVC6200f Digital Valve Controller November 2010 278 E ...
Page 308: ...DVC6200f Digital Valve Controller November 2010 296 F ...
Page 312: ...DVC6200f Digital Valve Controller September 2010 300 Notes G Glossary ...
Page 324: ...DVC6200f Digital Valve Controller November 2010 312 F Index ...