![Emerson FIELDVUE DVC6200f Instruction Manual Download Page 232](http://html.mh-extra.com/html/emerson/fieldvue-dvc6200f/fieldvue-dvc6200f_instruction-manual_102256232.webp)
DVC6200f Digital Valve Controller
November 2010
220
HOUSING
W9924-1
CABLE TO TRAVEL SENSOR
PRINTED WIRING
BOARD ASSEMBLY
CABLE
TO TERMINAL BOX
TERMINAL
BOX
MODULE BASE ASSEMBLY
Figure 7-1. Printed Wiring Board Cable Connections
Note
The module base is linked to the
housing by two cable assemblies.
Disconnect these cable
assemblies after you pull the
module base out of the housing.
CAUTION
To avoid affecting performance of the
instrument, take care not to damage
the module base seal or guide surface.
Do not bump or damage the bare
connector pins on the PWB assembly.
Damaging either the module base or
guide surface may result in material
damage, which could compromise the
instruments ability to maintain a
pressure seal.
3. Pull the module base straight out of the housing
(key 1). Once clear of the housing, swing the module
base to the side of the housing to gain access to the
cable assemblies.
4. The digital valve controller has two cable
assemblies, shown in figure 7-1, which connect the
module base, via the printed wiring board assembly, to
the travel sensor and the terminal box. Disconnect
these cable assemblies from the printed wiring board
assembly on the back of the module base.
Replacing the Module Base
Refer to figure 8-2 key number locations. Refer to
figure 7-2 for a view of the back of the PWB assembly
sub-module.
Note
To avoid affecting performance of the
instrument, inspect the guide surface
on the module and the corresponding
seating area in the housing before
installing the module base assembly.
These surfaces must be free of dust,
dirt, scratches, and contamination.
Ensure the module base seal is in
good condition. Do not reuse a
damaged or worn seal.
1. Ensure the module base seal (key 237) is properly
installed in the housing (key 1). Ensure the O-ring
(key 12) is in place on the module base assembly.
2. Connect the terminal box connector to the PWB
assembly (key 50). Orientation of the connector is
required.
7
Summary of Contents for FIELDVUE DVC6200f
Page 42: ...DVC6200f Digital Valve Controller November 2010 30 4 ...
Page 60: ...DVC6200f Digital Valve Controller November 2010 48 4 ...
Page 108: ...DVC6200f Digital Valve Controller November 2010 96 4 ...
Page 122: ...DVC6200f Digital Valve Controller November 2010 110 4 ...
Page 188: ...DVC6200f Digital Valve Controller November 2010 176 4 ...
Page 200: ...DVC6200f Digital Valve Controller November 2010 188 4 ...
Page 216: ...DVC6200f Digital Valve Controller November 2010 204 5 ...
Page 250: ...DVC6200f Digital Valve Controller November 2010 238 8 ...
Page 254: ...DVC6200f Digital Valve Controller November 2010 242 A ...
Page 284: ...DVC6200f Digital Valve Controller November 2010 272 D ...
Page 290: ...DVC6200f Digital Valve Controller November 2010 278 E ...
Page 308: ...DVC6200f Digital Valve Controller November 2010 296 F ...
Page 312: ...DVC6200f Digital Valve Controller September 2010 300 Notes G Glossary ...
Page 324: ...DVC6200f Digital Valve Controller November 2010 312 F Index ...