DL8000 Preset Instruction Manual
Revised February-2016
Communications Protocols
D-7
Although the exception code numbers raised are same for both Modbus
and DanLoad 6000 protocols, the DanLoad 6000 protocol has additional
exceptions.
D.1.6 Status Flags
The Status Flags parameter [63,0,119] maintains various process values
which the TAS uses to monitor the status of both the DL8000 and the
overall batching operation.
Note
:
These values accumulate in the TLP and do not currently appear
on any system report or screen.
Bit (Decimal)
Bit (Hex)
Description
00
00
Operating Mode is Manual
01
01
Primary Alarm
02*
02*
Passcode Entry in Progress
03*
03*
Operation Timed Out
04*
04*
Recipe Selected
05*
05*
Additive Selected
06*
06*
Preset Volume Entered
07*
07*
Keypad Data Available
08
08
Program Code Value Changed
09*
09*
Transaction in Progress
10*
0A*
Batch in Progress
11*
0B*
Key Pressed
12
0C
Transaction Ended
13
0D
Batch Ended
14*
0E*
Batch Aborted (not started)
15*
0F*
Intermediate Level Input Alarm Stopped
batch (not currently supported)
16
10
Batch in Configuration Mode
17
11
Batch Authorized
18
12
Transaction Authorized
19
13
Transaction End Requested
20
14
K&D Locked Out to Automation System
21
15
Batch Stopped (Resumable)
22
16
Program Mode
23*
17*
Flowing
An asterisk (*) indicates status flags that are reset when you power up
the DL8000. Refer to
Section D.8, Status Flag Descriptions
for a list of
status flags that the system sets or resets based on various conditions.
When the DL8000 is in Auto mode, you can clear some status flags
from the TAS using the Clear Status command (hex 0x13). You can
update the following flags: