DL8000 Preset Instruction Manual
Revised February-2016
DL8000 Keypad Display
E-51
Error Message
Description
Adtv not config
The parameter maximum additives
parameter [63,0,100] is set to
0
At the beginning of the calibration, the program checks for the “No
additive configured” and “Additive user program not running”
conditions. If you have forgotten to configure at least one additive or
have forgotten to start the Additive program, you cannot perform
additive calibration.
Assuming you have configured at least one additive and started the
Additive program, the following screen displays:
14/03/12 12:26:02
Select Additive
# of Injections
LEFT | RIGHT
Enter Additive Qty.
Enter Calib. Delay
(SELECT)
Additive 1
Press
SELECT
to choose an additive. The number of additives for
selection depends on the value defined in the Maximum Additives
parameter [63,0,100]. Once you select an additive, the system activates
the respective pump and block valve for the additive.
After you select an additive, you must enter the required number of
injections for calibration (defined in parameter [64,x,14]), the quantity
of additive (parameter [64,x,20]), and the calibration delay (parameter
[64,x,18]).
The preset validates the values you enter. If any errors exist, you cannot
proceed with calibration. If no errors are present, the system displays the
following loading screen:
14/03/12 12:26:02
Additive No
Corrected Qty.
Indicated Qty.
Additive Unit
No. of Injections
No. of Pulses
(START to inject)
Additive 1
0.000000
0.000000
CC
0
0
STOP to End)
Press
STOP
to end the calibration, or
START
to begin the calibration.
After the program performs the defined number of injections, the
program prompts you to enter a prover quantity: