DL8000 Preset Instruction Manual
D-50
Communications Protocols
Revised February-2016
Request
Component Value
[0x1A]
Results
The response frame includes the values of
following parameters for a given component:
Component Gross Total [69,x,30]
Component Net std or Mass Total [69,x,32 or
33] based on delivery type
Component Batch Gross Total [69,x,25]
Component Batch Net std or Mass Total
[69,x,27 or 28] based on delivery type
Component Avg (FWA) Batch Temperature
[69,x,61]
Component Avg (FWA) Batch Density
[69,x,100]
Component Avg (FWA) Batch Pressure
[69,x,72]
Average of last five valve closure pulses
[69,x,13;14;15;16;17]
Actual component % in batch [69,x,59]
Deviations
None
Request Power Fail
Date and Time
[0x1B]
Reads date and time at which DL8000 last lost its power. This value stores in
the system parameters [91,0,47].
Flags Immediately Set
None
Flags Immediately
Cleared
None
Exceptions
None
Supporting
Parameters
None
Results
None
Deviations
None